Modules Programming Guide - 9
DGP2-648BL
48-zone LED Keypad Module
This model does not support installer programming capabilities, therefore you cannot program other modules
or the panel on the combus using this unit.
*000=disabled; 001=A1; 002=A2; 003=A3; 004=A4. Do not assign the same display number to more than one section. A maximum of 4
partitions can be displayed on the keypad.
U= Default Settings
Section Data Description Default
[001] __/__/__ (000 to 004)* Partition 1 Display
001 = (LED A1)
[002] __/__/__ (000 to 004)* Partition 2 Display
002 = (LED A2)
[003] __/__/__ (000 to 004)* Partition 3 Display
003 = (LED A3)
[004] __/__/__ (000 to 004)* Partition 4 Display
004 = (LED A4)
[005] __/__/__ (000 to 004)* Partition 5 Display
000
[006] __/__/__ (000 to 004)* Partition 6 Display
000
[007] __/__/__ (000 to 004)* Partition 7 Display
000
[008] __/__/__ (000 to 004)* Partition 8 Display
000
Section [009] Keypad Options
Options OFF ON
[1]
Confidential Mode
U Disabled N Enabled
[2]
Exit Confidential Mode
U
Press key
N Enter code
[3]
Muting
U Disabled N Enabled
[4]
Beep on Exit Delay
N Disabled U Enabled
[5]
Chime on Zone Closure
U Disabled N Enabled
[6] to [8]
Future Use
N N/A N N/A
Section [010] Beep on Trouble
Options OFF ON
[1]
Beep on System Trouble/Clock Loss
U Disabled N Enabled
[2]
Beep on Communicator Trouble
U Disabled N Enabled
[3]
Beep on Module/Combus Trouble
U Disabled N Enabled
[4]
Beep on Zone Trouble
U Disabled N Enabled
[5] to [8]
Future Use
N N/A N N/A
Section [011] PGM & Keypad Tamper Options
Options OFF ON
[1]
PGM State
U N.O. N N.C.
[2]
PGM Deactivation Mode
U
Deactivati
on Event N
PGM Timer
[3]
PGM Base Time
U 1 second N 1 minute
[4]
Future Use
N N/A N N/A
[5]
Keypad Tamper
U Disabled N Enabled
[6] to [8]
Future Use
N N/A N N/A