ERROR (Red): Indicates a problem with
the module.
BUS RX (Green): Flashes when receiving
information from the
panel.
BUS TX (Red): Flashes when transmitting
information to the panel.
RF RX(Green): Flashes when receiving
wireless information.
RF TX(Yellow): Flashes when transmitting
wireless information.
Connect to any device such as a
garage door, light or siren.
Connect to an external Power
Supply (PS-17 recommended)
Use a relay if the
current draw will
exceed 150mA.;
System Reset: Press and hold
the Programming button for 5
seconds, the BUS RX LED will
flash. Release the button and
press it again while the LED
flashes to reset the module to its
default values. This is only
possible in the first 30 seconds
after the MG-RTX3 is powered
up.
Anti-Tamper Switch
Refer to Module Connection Drawings on
page 39 for information.
Refer to PGM Connection
for connection information.
Connect to a 307USB and use WinLoad’s In-Field
Firmware Upgrade Application to upgrade the
firmware
Connect the detection devices to the APR-ZX8
input terminals exactly as shown in the control
panel Reference & Installation Manual.
Pressing the
"Disable
Locate" switch
will disable a
"Locate"
request coming
from the control
panel.
Input terminal Z8
can be used as an
anti-tamper switch
input Option [1]:
Section [001]
External
Anti-
Tam pe r
Switch
(N.C.)
Refer to Module Connection drawings on
page 39 for information.
Open Collector
(Negative Trigger)
12 Vdc 50 mA
To drive more than
50mA
use a 12Vdc relay