Splice all
cables here
Connecting Access Control Devices to the DGP2-ACM12
Caution:
Disconnect
battery before
replacing fuse.
Digiplex/ Digiplex
EVO Control Panel
Rechargeable
Battery
YUASA model
#NP7-12 UL/ULC
12Vdc/4Ah
When using the on-board power supply, the
12Vdc power supply output will automatically
shut down if the current exceeds 1.1A (see
Inset 1).
Reader
Cable
Routing Cable
Do not use twisted pairs or
twisted cables for the routing
cable.
CR-R880-BL Indoor/Outdoor
Proximity Reader with 10cm
(4in) Read Range
Also supports the CR-R885-BL.
If a routing cable is required to connect the reader to the
module, the routing cable must be shielded. Do not
connect the shield wires together at the reader cable
splice. With the shield wire already terminated at the
reader, simply terminate the shield at the module. Do not
connect the shield to the black wire at the reader cable
splice.
The external negative trigger can be connected to either the PGM output of the control
panel or module or to a push button. Once connected, either the programmed event or
the pressing of the push button will send a signal to the external negative trigger and
open the door lock.
To PGM output
When connecting the diode to the door lock,
be sure to connect the cathode of the diode to
the positive (+) voltage and the anode to the
negative (-) voltage.
Door Lock
See Inset 1
Door Contact
Must be
connected to CT
terminal**
Paradoor 460
Request to Exit device must be connected to REX terminal***
* =
** =
*** =
Combus
12Vdc
AWG #14
single
conductor solid
copper wire
Press to
toggle the
AUX output
DGP-ACM12
CONV4USB
Use one
transformer to
power multiple
modules
From Transformer
Connect to
another module
compatible with
transformer
sharing
External Negative Trigger
External Tamper
Switch (N.C.)
Ground clamp
Cold water pipe
grounding
Follows control panel’s EOL definition.
If the door contact is not used, install a
jumper or a 1kW resistor across the AUX-
and CT terminals depending on the
control panel’s EOL definition.
If the Request for Exit device is
not used, place a jumper
across the AUX- and REX
terminals.
Inset 1
Connecting the Anti-
Tamper Switch
Connecting the External Negative Trigger
Transformer Sharing
Connecting for Firmware Upgrade
Connecting a 7-Wire Routing Cable Cable