Digiplex EVO641R Manual de instalación Pagina 43

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 60
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 42
Modules Programming Guide - 43
Motion Detector Modules (DGP2-50/60/70)
PCB Height Adjustment
DGP2-50/60/70 is designed for optimal performance at
a height of 2.1m (7ft), but can be installed lower or
higher. After you have installed the motion detector,
ensure that the PCB Height Markings match the
installation height. The installation height is measured
from the ground to the base of the motion detector's
cover.
For example, if the motion detector is installed at a
height of 2.1m (7ft), the PCB should then be adjusted
to 2.1m (7ft). To adjust the PCB height, remove the
PCB screw and align the PCB Height Tab with the
desired height marking on the PCB.
Addressable High-Security
Motion Detectors
(DGP2-70)
Addressable Digital
Motion Detectors
(DGP2-50/60)
1) LENS
2) BEZEL PIN
3) SENSOR (S)
4) ANTI-TAMPER SWITCH
5) PCB SCREWS
6) METAL SHIELD
7) DETECT/ALARM LED (red)
Flashing: Unable to communicate with the control
panel.
8) PROTECT INDICATOR LED (green)
Locate: If activated, the LED will flash until the
Anti-Tamper Switch is pressed or the detector’s
serial number is entered
9) PCB HEIGHT TAB
To Digiplex
EVO control
panel.
Vista de pagina 42