Modules Programming Guide - 29
Only Event Groups 000 to 055, 062 and 063 can be used to program the module’s PGM.
U = Default setting
Section [004] PGM Options
Options OFF ON
[1] PGM Deactivation After U
Deactiva
tion Event N
PGM Timer
[2] PGM Normal State U N.O. N N.C.
[3] PGM Base Time U 1 second N 1 minute
[4] & [5] Special
N see table
N see table
N see table
N see table
[6] Reader Locate Feedback U Visual N Visual & audible
[7] Unlock Door on Fire Alarm U Disabled N Enabled
[8] AC and Battery Supervision U Enabled N Disabled
Section Data Description Default
[005] __/__/__ (000 to 255 x 1 minute; 000 = Instant) AC failure report delay
030
[006] __/__/__ (001 to 255 seconds) Door Unlocked Period
005
[007] __/__/__ (001 to 255 seconds added to section [006]) Door Unlocked Period extension
015
[008] __/__/__ (001 to 255 seconds) Door Left Open Interval
060
[009] __/__/__ (001 to 255 seconds)
Time to start pre-alarm before alarm is triggered
Door Left Open Pre-Alarm Timer 015
[010] __/__/__ (001 to 255 seconds) Beep timer for Door Left Open Alarm
005
[011] __/__/__ (001 to 255 seconds) Beep timer for Door Forced Open alarm
005
[012] __/__/__ (000 to 255; refer to option [3] in section [004]) PGM timer
005
Section [013] Door Unlocked Schedule
Start Time End Time Days (Turn ON or OFF)
SMTWTFSH
Schedule A: ___ ___ : ___ ___ ___ ___ : ___ ___
12345678
Schedule B: ___ ___ : ___ ___ ___ ___ : ___ ___
12345678
Sections PGM Activation Event
[014] __/__/__ Event Group
[015] __/__/__ Feature Group
[016 __/__/__ Start #
[017 __/__/__ End #
Sections PGM Deactivation Event
[018] __/__/__ Event Group
[019 __/__/__ Feature Group
[020] __/__/__ Start #
[021] __/__/__ End #
[4] [5]
N Card Only OFF OFF
N PIN Only ON OFF
N Card and PIN OFF ON
U Card or PIN ON ON
Comentarios a estos manuales