Digiplex EVO641R Manual de instalación Pagina 10

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 60
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 9
10 - Modules Programming Guide
Refer to Appendix 1: Programming PGMs on page 52 for the PGM Table. Only Event Groups 000 to 055 can be used to program the
module’s PGM.
Sections Data Description Default
[012] __/__/__ (005 to 255 seconds) Confidential Mode Timer
120
[013] __/__/__ (001 to 255; see option [3] in section [011])PGM Timer
005
Sections PGM Activation Event
[014] __/__/__ Event Group
[015] __/__/__ Feature Group
[016] __/__/__ Start #
[017] __/__/__ End #
Sections PGM Deactivation Event
[018] __/__/__ Event Group
[019] __/__/__ Feature Group
[020] __/__/__ Start #
[021] __/__/__ End #
Sections Description
[030] Test PGM: Activates the PGM for 8 seconds to verify if the PGM is functioning properly.
[040] Zone Display Reset: Resets zone display sections [101] to [196] to default values.
Vista de pagina 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 59 60

Comentarios a estos manuales