3.4 Display Entry Delay Timer
SECTION [003]: OPTION [3]
The Entry Delay Timer will be programmed to provide the user time
to enter their User Access Code before the alarm is triggered. The
Entry Delay Timer's countdown can be displayed on the LCD
screen.
Option [3] OFF= Will not display the Entry Delay Timer (default)
Option [3] ON = LCD screen will display Entry Delay Timer
3.5 Confidential Mode
SECTION [003]: OPTIONS [4] AND [5]
If Confidential Mode is enabled and no actions are performed on
the keypad for a period of time, the LCD will appear as shown in
Figure 30 (page 52) and the “AC” and “STATUS” LED will be OFF.
The period of time in which no action is performed is defined by the
Confidential Mode Timer (005-255 seconds; refer to section
section 3.6 on page 52). Confidential Mode is activated by enabling
option [4]. Option [5] regulates whether the LCD screen will be
activated at the touch of a button or only when an access code is
entered.
Once the LCD screen is activated (by code or button), Normal
Mode will appear and display the date and time as shown in Figure
30 on page 52. The status of the areas, the open zones for every
area the keypad is assigned, the Alarm Memory Display (if
necessary) and the Trouble Display (if necessary. See DGP-848
User Manual) will also scroll on the LCD screen. By default, options
[4] and [5] are OFF.
Section [003]:
Option [4] OFF= Normal Mode
Option [4] ON = Confidential Mode
Option [5] OFF= LCD screen activated by entering an access code
Option [5] ON = LCD screen activated by pressing a button
Figure 30 : LCD Screen
3.6 Confidential Mode Timer
SECTION [007]
Section [007] determines the amount of time without action before
the keypad enters Confidential Mode. For more information on
Confidential Mode, refer to Confidential Mode on page 52.. The
Confidential Mode Timer can be set from 005 seconds to 255
seconds. Default: 120 secs.
3.7 Time Display Option
SECTION [003]: OPTION [8]
The LCD keypad comes with a time display option that can display
the date as year/month/day or as day/month/year.
Option [8] OFF= Date displayed as yy/mm/dd (default)
Option [8] ON = Date displayed as dd/mm/yy
3.8 Muting
SECTION [004]: OPTION [1]
The keypad can be programmed not to emit audible sounds,
including Chimed zones. During Muting, the keypad will only emit
the Confirmation Beep, Rejection Beep, and beep when a button is
pressed.
Option [1] OFF= Audible sounds (default)
Option [1] ON = Mute
3.9 Beep on Exit Delay
SECTION [004]: OPTION [2]
The keypad can beep once every second during the Exit Delay
Timer. During the final 10 seconds, it will beep more rapidly to
provide a final warning before the area is armed.
Option [2] OFF= Exit Delay beep disabled
Option [2] ON = Exit Delay beep enabled (default)
3.10 Chime on Zone Closure
SECTION [004]: OPTION [4]
During the Chime Zone Time Period that the user sets, the keypad
can emit an intermittent beep whenever a zone with the Chime
feature enabled closes (see DGP-848 User Manual for details on
Chime Zones). If the user does not set the Chime Zone Time
Period and this option is enabled, the Chime Zones will always
beep upon closure.
Option [4] OFF= Chime on Zone Closure disabled (default)
Option [4] ON = Chime on Zone Closure enabled
3.11 Beep on Trouble
SECTION [005]: OPTIONS [1] TO [4]
Potential troubles have been sorted into groups. With these options
enabled, the keypad will emit an intermittent beep tone whenever a
trouble condition from the Trouble Groups occurs in the system.
The intermittent beep will remain activated until the user enters the
Trouble Display or if the trouble is resolved. For a list of the
troubles, see the DGP-848 Reference and Installation Manual. The
intermittent beep will be re-initialized whenever the trouble
condition re-occurs.
O
ption [1] OFF = Beep disabled: System Troubles and Clock Loss
Option [1] ON = Beep enabled: System Troubles and Clock Loss
Option [2] OFF= Beep disabled: Communicator Troubles
Option [2] ON = Beep enabled: Communicator Troubles
Option [3] OFF= Beep disabled: Module and Combus Troubles
Option [3] ON = Beep enabled: Module and Combus Troubles
Option [4] OFF= Beep disabled: all Zone Troubles
Option [4] ON = Beep enabled: all Zone Troubles
3.12 Keypad Tamper Enable
SECTION [006]: OPTION [5]
With tamper enabled and the on-board tamper switch is triggered,
a Tamper report will be sent to the control panel via the combus.
Option [5] OFF= Keypad's tamper is disabled (default)
Option [5] ON = Keypad's tamper is enabled
3.13 Time Format
SECTION [005]: OPTION [7]
This feature determines whether the time shown on the screen will
be displayed using the International time format (24Hr. clock) or the
US time format (AM/PM).
Option [7] OFF= Time uses the International time format (default).
Option [7] ON = Time uses the US time format.
3.14 Combus Voltmeter
The combus voltmeter displays the real-time voltage and verifies if
the combus is supplying sufficient power at the keypad module’s
location. Readings will appear on the LCD screen. A reading of
10.5V indicates that the voltage is too low. This may occur when
too many modules are connected to the combus, a module is
installed too far from the panel or if the system is running on the
Vista de pagina 55
1 2 ... 51 52 53 54 55 56 57 58 59 60 61 ... 67 68

Comentarios a estos manuales

Sin comentarios

Husqvarna 355 podręczniki

Instrukcje obsługi i podręczniki użytkownika dla Narzędzie do benzyny Husqvarna 355.
Dostarczamy 1 pdf podręczników Husqvarna 355 do pobrania za darmo według typów dokumentów: Instrukcja Użytkownika






Więcej produktów i instrukcji dla Narzędzie do benzyny Husqvarna

Modele Rodzaj dokumentu
1153136-95 Instrukcja Użytkownika   Husqvarna 1153136-95 User Manual, 36 strony
1153158-95 Instrukcja Użytkownika   Husqvarna 1153158-95 User Manual, 44 strony
345e EPA III Instrukcja Użytkownika   Husqvarna 345e EPA III User Manual, 44 strony
55 Instrukcja Użytkownika   Husqvarna 55 User Manual, 40 strony
346XP 351 Instrukcja Użytkownika   Husqvarna 346XP 351 User Manual, 36 strony
339XP Instrukcja Użytkownika   Husqvarna 339XP User Manual, 44 strony
1153183-95 Instrukcja Użytkownika   Husqvarna 1153183-95 User Manual, 44 strony
325P4 Instrukcja Użytkownika   Husqvarna 325P4 User Manual, 28 strony
1153181-95 Instrukcja Użytkownika   Husqvarna 1153181-95 User Manual, 44 strony
335XPT Instrukcja Użytkownika   Husqvarna 335XPT User Manual, 36 strony
357XP Instrukcja Użytkownika   Husqvarna 357XP User Manual, 36 strony
346XP/ 351 Instrukcja Użytkownika   Husqvarna 346XP/ 351 User Manual, 44 strony
40 Instrukcja Użytkownika   Husqvarna 40 User Manual [en] , 36 strony
536 LIXP Instrukcja Użytkownika   Husqvarna 536 LIXP User Manual, 44 strony
140 Instrukcja Użytkownika       Husqvarna 140 User Manual, 420 strony
365 Instrukcja Użytkownika   Husqvarna 365 User Manual, 40 strony
1153136-49 Instrukcja Użytkownika     Husqvarna 1153136-49 User Manual, 100 strony
42 Instrukcja Użytkownika   Husqvarna 42 User Manual, 36 strony
223L Instrukcja Użytkownika     Husqvarna 223L User Manual, 20 strony
343F EN Instrukcja Użytkownika   Husqvarna 343F EN User Manual, 44 strony