DGP-848 Control Panel 45
15.9 Call Back Feature
SECTION [522]: OPTION [1]
For additional security, when a computer using WinLoad attempts
to communicate with the control panel, the control panel can hang
up and call the computer back to re-verify identification codes and
re-establish communication. When the control panel hangs up,
WinLoad automatically goes into Wait For Call Mode, ready to
answer when the control panel calls back. Please note that the PC
Telephone Number must be programmed in order to use the Call
Back feature.
16 User Features
16.1 Arming and Disarming Features
Partitions can be armed using various arming methods. Refer to
section 16.1.7 for information on how to arm.
16.1.1 Regular Arming
This method is used for the everyday arming of the system. All
zones within the partition must be closed to arm the system. The
system can also be Regular armed by using a One-Touch Feature
(see section 6.8 on page 20) or a keyswitch (see section 5.4.6 on
page 19). All users are able to Regular arm the partition(s)
assigned to their user access codes.
16.1.2 Stay Arming
Stay arming will partially arm the partition to permit the user to
remain in the protected area. The programmed Stay Zones (see
section 4.4.3 on page 14) will not arm when Stay arming a partition.
For example, the doors and windows can be armed without arming
the motion detectors. The system can also be Stay armed by using
a One-Touch Feature (see section 6.8 on page 20) or a keyswitch
(see section 5.4.3 on page 18). Only user access codes with the
Stay and Instant Arm option enabled can Stay arm a partition.
16.1.3 Stay Arming with Delay
Stay arming with Delay functions like Stay arming except armed
zones can be programmed with an Entry Delay Timer (see section
4.2.9 on page 13). If these zones are accidently triggered, the timer
will start to allow the user time to disarm the partition(s).
16.1.4 Instant Arming
This feature is similar to Stay arming. Instant arming will partially
arm the partition to permit the user to remain in the protected area,
but all zones, including the entry/exit point, are changed to instant
alarm zones. Therefore, if any armed zone is breached, the alarm
will instantly be triggered. The system can also be Instant armed by
using a One-Touch Feature (see section 6.8 on page 20) or a
keyswitch (see section 5.4.5 on page 19). Only user access codes
with the Stay and Instant Arm option enabled can Instant arm a
partition.
16.1.5 Instant Arming with Delay
Instant arming with Delay functions like Instant arming except
armed zones can be programmed with an Entry Delay Timer (see
section 4.2.9 on page 13). If these zones are accidently triggered,
the timer will start to allow the user enough time to disarm the
partition(s).
16.1.6 Force Arming
Force arming allows the user to arm a partition when Force zones
are open (see section 4.4.4 on page 14). Once the open zone in an
armed partition is closed, however, the system will then arm it as
well. This feature is commonly used when a motion detector is
protecting an area that is occupied by a keypad. For example,
during Force arming the motion detector will remain unarmed until
the user exits the area that it protects. The system will then arm the
motion detector. The system can also be Force armed by using a
One-Touch Feature (see section 6.8 on page 20) or a keyswitch
(see section 5.4.4 on page 18). Only user access codes with the
Force Arm option enabled can Force arm a partition.
16.1.7 How to Arm
The following section details how to arm the system using an LCD
or Grafica keypad.
For LCD keypads:
To arm, users:
1) Enter their [
ACCESS CODE].
2) Press the key corresponding to the desired arming method
(see Table 13). If the users have access to more than one
partition, they can press the key corresponding to the desired
partition or press [0] to arm all their assigned partitions.
For Grafica keypads:
To arm, users:
1) Enter their [
ACCESS CODE].
2) Using the scroll keys, highlight the desired arming method
(see Table 13) and then press the center action key (Ok). If
you have access to more than one area, proceed to step 3.
3) Highlight either Arm All Areas or Select Area(s) and then
press the center action key (Ok). If you selected the Select
Area(s) method, follow steps 4 and 5.
4) Highlight an area you wish to arm and then press the left
action key (Select). Repeat this step for any additional area.
5) Press the center action key (Arm)
Table 13: .Arming Methods
16.1.8 Disarming
Users can only disarm the partitions assigned to their user access
codes. User access codes with the Arm Only option (see section
13.5.4 on page 39) enabled cannot disarm.
For LCD keypads:
To disarm, users:
1) Enter through a designated entry. The Entry Delay Timer will
begin.
2) Enter their [
ACCESS CODE].
Arming Method LCD Grafica
Regular [
ARM]
(Arm System)
Stay [
STAY]
(Stay Arm)
Instant [5]
(Instant Arm)
Force [FORCE]
(Force Arm)
Comentarios a estos manuales