46 Reference & Installation Manual
3) Press the [
DISARM] key. If the users have access to more than
one partition, they can press the key corresponding to the
desired partition or press [0] to disarm all their assigned
partitions.
For Grafica keypads:
To disarm, users:
1) Enter through a designated entry. The Entry Delay Timer will
begin.
2) Enter their [
ACCESS CODE].
3) Using the scroll keys, highlight Disarm and then press the
center action key (Ok). If you have access to more than one
area, proceed to step 4.
4) Highlight either Disarm All Areas or Select Area(s) and then
press the center action key (Ok). If you selected the Select
Area(s) method, follow steps 5 and 6.
5) Highlight the area you wish to disarm and then press the left
action key (Select). Repeat this step for any additional area.
6) Press the center action key (Disarm).
16.2 Bypass Programming
Bypass Programming allows users to program the alarm system to
ignore specified zones the next time the system is armed. For a
user to bypass a zone, the zone must have the Bypass option
enabled, the user access code must have the Bypass option
enabled, and the zone must be within the user access code’s
partition assignment.
For LCD keypads:
To bypass, users:
1) Enter their [
ACCESS CODE].
2) Press the [BYP] key.
3) Enter the zones’ 2-digit number.
4) Press [
ENTER] key to exit.
For Grafica keypads:
To bypass, users:
1) Enter their [ACCESS CODE].
2) Using the scroll keys, highlight Bypass and then press the
center action key (Ok).
3) Highlight the zone that you wish to bypass and then press the
left action key (Bypass). Repeat this step for any additional
zone.
4) Press the right action key (Back) to save the data.
Users can also activate Bypass Recall. Bypass Recall reinstates all
the zones that were bypassed the last time the partition(s)
assigned to the user access code were armed.
For LCD keypads:
To activate Bypass Recall, users:
1) Enter their [
ACCESS CODE].
2) Press the [
BYP] key.
3) Press the [
MEM] key.
4) Press [
ENTER] key to exit.
For Grafica keypads:
To activate Bypass Recall, users:
1) Enter their [
ACCESS CODE].
2) Using the scroll keys, highlight Bypass and then press the
center action key (Ok).
3) Highlight Bypass Recall and then press the center action key
(Ok).
16.3 Chime Zones
The keypads can be programmed to emit rapid, intermittent beeps
whenever designated zones within their assigned partitions are
opened or when they are opened within a certain time period.
These zones are Chime Zones. The instructions that follow are for
LCD keypads. For Grafica keypads, a complete Grafica user
manual is available on our website at www.paradox.ca.
For LCD keypads:
To program a Chime Zone, users:
1) Enter their [
ACCESS CODE].
2) Press the [9] key.
3) Press the [1] key.
4) Enter the zones’ 2-digit number.
5) Press [
ENTER] key to save.
To program a time period when the Chime Zones are activated,
users:
1) Enter their [
ACCESS CODE].
2) Press the [9] key.
3) Press the [2] key.
4) Enter the time that keypads will start beeping when Chime
Zones are opened according to the 24-hour clock (i.e. 9AM is
09:00 and 9PM is 21:00).
5) Enter the time that keypads will stop beeping when Chime
Zones are opened according to the 24-hour clock (i.e. 9AM is
09:00 and 9PM is 21:00).
6) Press [
ENTER] key to save.
16.4 Access Codes
Refer users to the appropriate manual: LCD Keypad System
Manager’s Manual or LED Keypad User Manual.
16.5 Normal and Confidential Modes
For LCD Keypads:
When no actions are being performed on the keypad, the keypad
will remain in Normal Mode as shown in Figure 23 and will
automatically display:
The current status of the zones for every area the keypad is
assigned
The Alarm Memory Display if any alarms have occurred
The Trouble Display if any troubles are occurring
The current state of the Indicator Lights
In Confidential Mode:
The zones and status messages will NOT be displayed
• The Indicator Lights will not illuminate
Depending on how the keypad was programmed, the user must
press a key or enter a user access code to illuminate the Indicator
Lights and activate Normal Mode.