DGP-848 Control Panel 43
14.10 Global Access Door Features
14.10.1 Burglar Alarm On Forced Door
SECTION [537]: OPTION [5]
An Access Door can be assigned to a zone in the Digiplex security
system to also be protected by the burglar alarm. If an armed
Access Door is forced open (see section 14.2 on page 41), it can
send a signal to the control panel to trigger a burglar alarm and to
report to the Monitoring Station. The burglar alarm is generated
instantly regardless of the zone’s definition (i.e. entry delay is
ignored).
For this feature to function, the following must be done:
• Install a door contact (see appropriate Digiplex Module
Reference & Installation Manual)
• Assign the Access Door to a zone (see section 4 on page 11)
• Enable option [4] in section [537]: Log Door Forced Open
Restore (optional) (see section 14.9 on page 42)
• Enable option [5] in section [537]: Burglar Alarm on Forced
Door (see section 14.10.1)
Option [5] ON = Burglar Alarm on Forced Door enabled
Option [5] OFF = Burglar Alarm on Forced Door disabled (default)
14.10.2 Skip Exit Delay When Arming With Access Card
SECTION [537]: OPTION [6]
When an Access Card is presented to a reader twice within
approximately 5 seconds with the door closed, some or all the
partitions (see section 14.5 on page 41) assigned to the Access
Door can arm with or without starting the Exit Delay. This feature is
useful when the reader is outside the partition so the partition will
be armed immediately.
Option [6] ON = The Exit Delay will not be triggered
Option [6] OFF = The Exit Delay will be triggered (default)
14.10.3 Burglar Alarm On Door Left Open
SECTION [537]: OPTION [7]
An Access Door can be assigned to a zone in the Digiplex security
system to also be protected by the burglar alarm. Each Access
Door is programmed with a period of time that it is allowed to
remain open. Once the door has been open longer than the
programmed time period, a signal can be sent to the control panel
to trigger the burglar alarm and to report to the Monitoring Station.
For this feature to function, the following must be done:
• Install a door contact (see appropriate Digiplex Module
Reference & Installation Manual)
• Assign the Access Door to a zone (see section 4 on page 11)
• Enable option [3] in section [537]: Log Door Left Open Restore
In Event Buffer (optional) (see section 14.9 on page 42)
• Enable option [7] in section [537]: Burglar Alarm on Door Left
Open (see section 14.10.3)
Option [7] ON = Burglar Alarm on Door Left Open enabled
Option [7] OFF = Burglar Alarm on Door Left Open disabled
(default)
14.10.4 Door Access During Clock Loss
SECTION [537]: OPTION [8]
If the system registers a Clock Loss Trouble, the system will no
longer be able to recognize the Schedules. Only the System
Master Code and user access codes with the Master feature
enabled can reset the clock when option [8] is enabled. To avoid a
Clock Loss Trouble, the Digiplex Time Module (DGP2-TM1) can be
installed on the control panel. Until the Clock is reset, the Access
Control system can be programmed to grant access to:
Option [8] ON = the System Master Code, User Access Codes
with the Master feature or Schedule 00 (00=all
times) enabled
Option [8] OFF = all users regardless of their programmed
Schedule (default)