DGP-848 Control Panel 37
on the module will begin to flash until the serial number is re-
entered into section [952] or the appropriate tamper or unlocate
switch on the module is pressed.
12.11 Module Programming
SECTION [953]
All modules connected to the combus are programmed through the
control panel. Therefore, if you wish to program a module, enter
section [953] to enter Module Programming Mode (see section 3.2
on page 9) and key in the module's serial number. At this point, any
sections entered will be those of the selected module. For details
on how to program the modules, refer to the module's Installer’s
Guide or the module’s Programming Guide. To exit this mode,
press the [
CLEAR] key on LCD keypads, or the right action key
(Exit) on Grafica keypads, as many times as needed to return to
the desired screen.
12.12 Module Broadcast
SECTION [954]
This feature allows you to copy the contents of all programming
sections from one module to one or more of the same type of
module.
The Module Broadcast feature will only work when a
module is broadcasting its data to a module or to
modules of the same type and model number. For
example, an APR-PRT1 (Printer Module) cannot
broadcast to an APR3-PRT1. Likewise, a DGP module
cannot broadcast to a DGP2 module.
1) Press and hold the [0] key.
2) Enter the [
INSTALLER CODE] (Default is 000000).
3) Enter [954].
4) Enter the source module’s 8-digit [
SERIAL NUMBER].
5) Enter the destination module’s 8-digit [SERIAL NUMBER].
Repeat this step once for every additional module.
6) For LCD keypads, press [
ACC]. For Grafica keypads, press the
center action key (Start).
For example: Using an LCD keypad, you've completed the
programming of a zone expansion module (sn#34540033) and you
wish to program another two zone expansion modules
(sn#34540075 and sn#34412100) with the same settings:
1) Press and hold the [0] key.
2) Enter the [
INSTALLER CODE].
3) Enter [954].
4) Enter 34540033, 34540075, and 34412100.
5) Press [
ACC].
The control panel will automatically copy the contents of 34540033
into the other two zone expansion modules.
12.13 Remove Module
SECTION [955]
After entering section [955], the control panel will scan all modules
connected to the combus. If any missing modules are detected (i.e.
detector removed from the combus) during this scan, the control
panel will erase the module's serial number and remove the
module from the control panel's memory.
12.14 Serial Number Viewing
SECTION [900]
This feature allows you to view the serial number of the control
panel as well as the serial numbers of all modules connected to the
combus.
For LCD keypads: After entering section [900], the keypad will
display the 8-digit serial number of the control panel. Use the [
S]
and [
T] keys to scroll through the serial number of each module
connected to the combus.
For Grafica keypads: After entering section [900], the keypad will
display the 8-digit serial number of the control panel. Press the
center action key (Next) to scroll through the serial number of each
module connected to the combus.
12.15 Power Save Mode
SECTION [504]: OPTIONS [4]
When the control panel is running on the backup battery (no AC),
the control panel can set all keypads into a “sleep mode” or Power
Save Mode. In Power Save Mode the keypad's backlight and LEDs
will be disabled until a key is pressed, an alarm occurs or an Entry
Delay is triggered.
12.16 Auto Trouble Shutdown
SECTION [218]
If, in a 24-hour period, a trouble has occurred more than the
number of times programmed in section [218], the control panel
will no longer report this trouble. Enter a value (001 to 015, 000 =
disabled) into section [218]. Please note that each trouble has its
own counter. This counter is reset every day at midnight or when a
Module Scan is performed (see section 12.6 on page 36). Also,
note that it cannot be set to more than 15.
12.17 No AC Fail Display
SECTION [503]: OPTION [7]
With option [7] in section [503] enabled, the control panel will not
display the AC Failure as a trouble. This means that when an AC
Failure occurs when this option is on:
the AC LED will extinguish
the trouble will not appear in the Trouble Display
the keypad will not beep to indicate the trouble
the AC Failure report code will be reported.