Digiplex DGP2-648BL Manual de usuario Pagina 28

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 44
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 27
24 User Manual
8.0.1 Group [1]: System
Trouble [1]: AC Failure
This means that your system is running on the backup battery. The
AC light on your keypad will be turned off during a power failure. If
this trouble occurs when your establishment is not experiencing a
power failure, call your security company for repairs.
Trouble [2]: Battery Trouble
This means the backup battery is disconnected or needs to be
recharged or replaced.
Trouble [3]: AUX Current Limit
Devices connected to the system have exceeded current limits. The
auxiliary output will shutdown until the troubled has been rectified.
Trouble [4]: Bell Current Limit
The bell of siren connected to the system has exceeded current
limits. The bell/siren output will shutdown until the trouble is rectified.
Trouble [5]: Bell Absent
The system has detected that the bell or siren is not connected.
8.0.2 Group [2]: Communicator
Trouble [1]: TLM1
The control panel is unable to access the main telephone line.
Troubles [2]-[5]: Fail to Communicate
The control panel tried all assigned telephone numbers and failed to
contact the Monitoring Company.
Trouble [6]: Fail to Communicate PC
The control panel is unable to communicate with the WinLoad software.
8.0.3 Group [5]: Zone Tamper
The numerical LEDs for the zone or zones that have been tampered
with will be illuminated.