Digiplex LED Keypad 21n
7.3 Area Assignment
In a partitioned system the system can be divided into distinct
protected areas. Programming access to a specific area or areas is
called Area Assignment. User Access Codes are only able to
perform actions (arming, disarming, etc.) in the area(s) the code is
Press option ON/OFF Option Description
[6] Stay and Instant Arm
OFF (default) Stay and Instant Arm feature disabled.
ON Stay and Instant Arm feature enabled.
Can Stay or Instant Arm the system.
[7] Force Arm Feature
OFF (default) Force Arm feature disabled.
ON Force Arm feature enabled.
[8] Area Access
OFF (default) User Access Code obeys the keypad’s area
assignment in a partitioned system. When
you enter your user code, your keypad will
permit access only to areas it controls. This
feature applies to both options.
ON When option [8] is ON, the keypad will
permit access to all the areas assigned to
the User Access Code. When option [8] is
OFF, the keypad will only permit access to
the areas it controls. This option is active
but not functional on the DGP2-648BL
keypad.