22 Reference & Installation Manual
5.4.1 Door Forced Open Access Alarm
S
ECTION [006]: OPTION [3]
If an Access Control door is opened without an Access Control
Card, a User Access Code or receiving a Request for Exit, an
Access Alarm can be generated. A Burglar Alarm can also be
generated. When the door is closed during an Access Alarm,
the Door Forced Open Restore event can be logged in the
Event Buffer. When the Door Forced Open Alarm is disabled,
the following sections are also disabled:
Option [3] OFF = Door Forced Open Alarm is disabled
(default)
Option [3] ON = Door Forced Open Alarm is enabled
5.4.2 Door Forced Open Feedback
S
ECTION [004]: OPTIONS [7] AND [8]
The Access Alarm can be either audible or silent and will either
beep as long as the Access Alarm is occurring or follow the
Beep Timer in section [013]. The sound of the Door Forced
Open Alarm resembles the rapid beep generated during the last
ten seconds of the Exit Delay.
Option [7] OFF = Door Forced Open Alarm is silent
Option [7] ON = Door Forced Open Alarm is audible (default)
If option [7] is enabled:
Option [8] OFF = Will beep as long as Door Forced Open Alarm
is occurring (default)
Option [8] ON = Door Forced Open Alarm follows Beep Timer.
(section [013])
Section
[004] Option [7] Door Forced Open Alarm
Option [8] Door Forced Open Alarm follows
[013] Beep Timer for Door Forced Open Alarm