10 Reference & Installation Manual
4.0 SYSTEM OPTIONS
4.1 Partition Assignment
SECTION [001]: OPTIONS [1] TO [8]
Keypads in the system can be assigned to one or more partitions.
Options [1] to [8] represent partitions 1 through 8 respectively. To
assign the keypad to a partition, enable the option that corresponds to
the desired partition. By default, partitions 1 to 8 are enabled.
Section [001] options [5] to [8] can only be used if the keypad is
connected to a DGP-NE96 control panel.
4.2 Display Access Code Entry
SECTION [003]: OPTION [1]
The digits of the User Access Codes can be displayed on the LCD
screen when they are entered.
Option [1] OFF= Digits are replaced by a “*“ (default)
Option [1] ON = Access Code digits will be displayed
4.3 Display Exit Delay Timer
SECTION [003]: OPTION [2]
Based on the user's needs, an Exit Delay Timer will be programmed to
provide the user time to exit the partition before the system is armed.
The Exit Delay Timer's countdown can be displayed on the LCD screen.
Option [2] OFF= Will not display Exit Delay timer (default)
Option [2] ON = LCD screen will display Exit Delay timer
DGP2641R_ei00.fm Page 10 Thursday, July 22, 2004 4:16 PM