38 - Digiplex Modules Programming Guide
Access Control Module (DGP2-ACM1P)
If you are not using the DGP2-ACM1P’s on-board
power supply, connect the “red” of the combus to
the “aux+” in order to power the module. Please
note that in such cases, the DGP2-ACM1P is
powered by the combus. Connect the devices to
either the DGP2-ACM1P’s auxiliary output (aux) or
to an external power supply. Also, if the on-board
power supply is not being used, you must disable
DGP2-ACM1P’s AC and Battery Supervision
feature (refer to page 26).
Splice all
cables here
See Inset 1
Connecting Access Control Devices to the DGP2-ACM1P
Caution:
Disconnect
battery before
replacing fuse.
Digiplex
Control
Panel
Rechargeable
Battery
YUASA model
#NP7-12 UL/ULC
12Vdc/4Ah
12Vdc Power Supply
Output
To power REX, door
contact and door lock
(see Inset 1)
When using the on-
board power supply,
the 12Vdc power
supply output will
automatically shut
down if the current
exceeds 1.1A (see
Inset 1).
Reader
Cable
Routing Cable
Do not use twisted pairs
or twisted cables for the
routing cable.
PosiProx
CR-R880-A
Also supports
the PosiPIN
PIN &
Proximity
Reader (CR-
R885-BL)
If a routing cable is required to connect the reader to the
module, the routing cable must be shielded. Do not connect
the shield wires together at the reader cable splice. With the
shield wire already terminated at the reader, simply terminate
the shield at the module. Do not connect the shield to the
black wire at the reader cable splice.
Connecting a Routing Cable
Connecting the External Negative Trigger
The external negative trigger can be connected to either the PGM output
of the control panel or module or to a push button. Once connected, either
the programmed event or the pressing of the push button will send a
signal to the external negative trigger and open the door lock.
PGM output from
control panel or
another module
Push Button
When connecting the diode to the door
lock, be sure to connect the cathode of
the diode to the positive (+) voltage and
the anode to the negative (-) voltage.
Door Lock
See Inset 1.
Door Contact
Must be connected to
CT terminal**
Paradoor 460
Request to Exit device must be connected to REX terminal***
Follows control panel’s EOL
definition.
If the door contact is not used,
install a jumper or a 1kW resistor
across the AUX- and CT
terminals depending on the
control panel’s EOL definition.
If the Request for Exit device is
not used, place a jumper across
the AUX- and REX terminals.
* =
** =
*** =
For information on the Access Control Module’s LEDs,
refer to Module LED Indications on page 30.
Refer to Module Connection Overview on page 30 for
information on how to connect the Access Control
Module’s PGM output (Figure 3). Before commencing
with the connections, please read the General Warnings
listed on page 30.