6 - Digiplex Modules Programming Guide
Section/option is only available with DGP2-641R/RB.
Section/option is only available with DGP2-641/BL
Section/option is only available with DGP2-641R/RB.
Section [510]: Download from Memory Key (PMC-3) to DGP2-641R/RB.
Section [520]: Upload from DGP2-641R/RB to Memory Key (PMC-3).
Section/option is only available with DGP2-641/BL.
Only Event Groups 000 to 055 and 070 can be used to program the module’s PGM. Refer to Appendix 1: Programming PGMs on page 41
for the PGM Table.
SECTION [006]: General Options 3 †
Option OFF ON Section/option is only available with DGP2-641R/RB.
* This option cannot be turned ON and will
always remain OFF.
[1] Card Activates Door Unlocked Schedule N Disabled.
U 1 second
[2] Door Left Open Alarm
U
Disabled
N Enabled
[3] Door Forced Open Alarm
U
Disabled
N Enabled
[4] PIN Entry on Keypad
U Enabled *
[5] Keypad Tamper
U Disabled
N Enabled
[6]
Relock Door
U Disabled
N Enabled
[7]
Future Use N N/A N N/A
[8]
Unlock on REX
U Disabled
N Enabled
Section Data Description Default
[007] __/__/__ (005 to 255 seconds) Confidential Mode Timer 120
[008] __/__/__ (000 to 255; see option [3] in section [006])PGM Timer 005
[008] __/__/__ (000 to 255 seconds) Door Unlocked Period 005
[009] __/__/__ (000 to 255 seconds added to section [008]) Door Unlocked Period Extension 015
[010] __/__/__ (000 to 255 seconds) Door Left Open Interval 060
[011] __/__/__ (000 to 25 seconds) Door Left Open Pre-Alarm Timer 015
[012] __/__/__ (000 to 25 seconds) Beep Timer for Door Left Open Alarm 005
[013] __/__/__ (000 to 25 seconds) Beep Timer for Door Forced Open Alarm 005
Section [017] Door Unlocked Schedule †
Start Time End Time Days (turn ON or OFF)
SMTWTFSH
Schedule A: ___ ___ : ___ ___ ___ ___ : ___ ___ 12345678
Schedule B: ___ ___ : ___ ___ ___ ___ : ___ ___ 12345678
Event Group Feature Group Start # End #
Section Section Section Section
PGM Activation [009]‡ __/__/__ [010]‡ __/__/__ [011]‡ __/__/__ [012]‡ __/__/__
PGM Deactivation [013]‡ __/__/__ [014]‡ __/__/__ [015]‡ __/__/__ [016]‡ __/__/__
Message Programming
Each section from [101] to [148], [200] to [204] and [301] to [396] contains one message with a maximum of 16 characters. The sections contain the
following messages:
Sections [101] to [148] = “Zone 01” to “Zone 48” respectively
Section [200] = “Paradox Security”
Sections [201] to [204] = “First Area”, “Second Area”, “Third Area”, and “Fourth Area”
Sections [301] to [396] = “Code 01” to “Code 96” respectively
After entering the section corresponding to the desired message, the message can be re-programmed to suit your installation needs as detailed in Table 1.
For example, section [101] “Zone 01” can be changed to “FRONT DOOR”.