Enter Section [0400], then
enter the number of the
zone you want to program
Enter the zone’s 8-digit
serial and 3-digit input
number (The input number
is not needed for module
with only one input)
Press [0] followed by [Enter]
to clear a zone’s serial
number.
Enter the zone’s parameters
(01) (*2*4***) default
Enter the zone’s report
codes
(00) (00) (00) (00) default
Enter the zone’s label
Press [ENTER] to save and
go to the next zone
Pressing [CLEAR] twice will
exit the zone programming
menus. Press [ENTER]
before pressing clear to
save your modifications.
Zone Definition Partition Zone Option
_____ _____ 1 2 3 4 5 6 7 8
0 - Disabled (default)
1 - Entry Delay 1
2 - Entry Delay 2
3 - Follow
4 - Instant
5 - 24Hr Buzzer
6 - 24Hr Burglary
7 - 24Hr Hold-up
8 - 24Hr Gas
9 - 24Hr Heat
A - 24Hr Water
B - 24Hr Freeze
C - Delayed 24Hr Fire
D - Standard 24Hr Fire
E - Stay Delay 1
F - Stay Delay 2
1 - Assigned to Partition 1
(default)
2 - Assigned to Partition 2
3 - Assigned to Partition 3
4 - Assigned to Partition 4
5 - Assigned to Partition 5
6 - Assigned to Partition 6
7 - Assigned to Partition 7
8 - Assigned to Partition 8
[1] Auto Zone Shutdown Enabled
[2] Bypass Enabled (default on)
[3] Stay Zone
[4] Force Zone (default on)
[5] [6] Zone Alarm Type
off off Steady Alarm
off on Pulsed Alarm
on off Silent Alarm
on on Report Only
[7] Intellizone
[8] Delay before Transmission
.
Ademco slow, Silent Knight fast, SESCOA, Ademco express or Pager formats:
Key-in desired 2-digit hex values from 00 to FF.
Ademco format:
Use section [4032] to program a set of default Ademco report codes from the
Automatic Report Code Programming on page 50. Then to program the remaining
report codes or to change some of the defaults, enter the individual sections and
key-in the desired 2-digit hex value found in the Contact ID Report Code List on
page 53.
SIA format:
Use section [4032] to program a set of SIA report codes from the Automatic Report
Code Programming on page 50. Codes that have not been set to default can be set
to default manually by entering FF in the appropriate section. To disable the
reporting of an event, enter 00 in the appropriate section
Alarm Report Code
Alarm Restore
Report Code
Tamper Report
Code
Tamper Restore
Report Code
__ / __ __ / __ __ / __ __ / __
In any Zone Programming option, pressing [ACC] will save the data and go
to the next zone on the same option screen. Pressing [TRBL] will save the
data and go to the previous zone on the same option screen.
Combus
Section [0400] is accessible only when using EVO641 and EVO641R keypads. Without section [0400], you can only program the
first 96 zones of the system using sections [0001] to [0096] for the zone’s serial number and input, sections [0101] to [0196] for
zone parameters, sections [0201] to [0296] for report codes and sections [0301] to [0396] for zone labels. In addition, with a
EVO48 panel, you can only program the first 48 zones with or without section [0400].
Comentarios a estos manuales