Digiplex -EVO- - 65 - Programming Guide
PCB Layout
Refer to the UL and ULC Warnings section of the EVO Reference & Installation Manual for UL and ULC warnings.
PLEASE NOTE:
When powering up the EVO control panel, the panel will begin a module scan to verify if all the modules connected to
the panel are operational. The scanning process will take between 30 and 120 seconds to complete depending on the
number of modules connected to the control panel. The module scan is complete when the LCD keypad begins to show
the partition status. Only after the module scan is complete will the control panel be fully operational.
When installing the combus wires in a noisy environment, or when connecting the combus across separate buildings,
you must use a shielded cable. Refer to Connecting the Combus in Noisy Environments on page 64.
Built-in RTC
See page 64
The sum of the
current drawn
from the BELL
and AUX must
be limited to 2.0A.
Exceeding this limit will
overload the panel
power supply and lead
to complete system
shutdown.
40VA transformer strongly recommended
(See “VDMP3 Installation Instructions” on
page 55.)
See “Updating Firmware
Using WinLoad” on page 59.