Digiplex -EVO- - 49 - Programming Guide
Other Settings and Modes
Paradox Memory Key (PMC-5)
[3966] __/__ Phone Number 2 Fail to Communicate [3978] Future Use
[3967] __/__ Phone Number 3 Fail to Communicate [3979] Future Use
[3968] __/__ Phone Number 4 Fail to Communicate [3980] __/__ Combus Fault Restore
[3969] Future Use [3981] __/__ Module Tamper Restore
[3982] __/__ ROM Check Error Restore
Trouble Restore Report Codes
[3983] __/__ Module TLM Restore
Section Report Code [3984] __/__ Module Failure to Communicate Restore
[3970] __/__ TLM1 Restore [3985] __/__ Printer Fault Restore
[3971] __/__ AC Failure Restore [3986] __/__ Module AC Failure Restore
[3972] __/__ Battery Failure Restore [3987] __/__ Module Battery Failure Restore
[3973] __/__ Auxiliary Supply Restore [3988] __/__ Module Auxiliary Failure Restore
[3974] __/__ Bell Output (Reconnected or Restored) [3989] Future Use
[3975] __/__ Clock Loss Restore [3990] __/__ Wireless Transmitter Battery Low Restore
[3976] __/__ Fire Loop Trouble Restore [3991] __/__ Wireless Transmitter Supervision Trouble Restore
[3977] Future Use
Section Description
[4000] Display Serial Number of Control Panel and All Modules Connected to the combus:
After entering section [4000], the keypad will display the 8-digit serial number of the control panel and firmware version.
For LCD Keypads: Use the [] and [] keys to scroll through the serial number of each module connected to the combus. The firmware
version of some modules will be displayed as well.
For Grafica Keypads: Press the center action key (Next) to scroll through the serial number of each module on the combus.
[4001] Module Reset:
Reset a module’s programmed contents to default by entering its serial number.
[4002] Locate/Unlocate Module:
Locate a specific module (e.g. detector, zone expander, etc.) connected to the combus by entering the module's serial number. The green
LOCATE” LED on the module will begin to flash until the serial number is re-entered or the appropriate “tamper” or “unlocate” switch on the
module is pressed.
[4003] Module Programming Mode:
Enter the serial number of the module you wish to program.
[4004] Module Broadcast:
Copy the contents of all programming sections from one module to one or more modules of the same type. Enter the serial number of the
source module, followed by the serial numbers of the modules you wish to program. To begin transferring data, press [
ACC] on LCD
keypads or the center action key (Start) on Grafica keypads.
Label Broadcast:
Copy user, door and partition labels from the control panel to all keypads and printer modules connected to the combus. To transmit the
labels, in section [4004], enter the control panel’s serial number. From the Destination screen, do not enter a serial number, but press
[
ACC] on LCD keypads or the center action key (Start) on Grafica keypads.
PLEASE NOTE: The Module and Label Broadcast feature will only work when a module is broadcasting its data to a module or to
modules of the same type and
model number. For example, an APR-PRT1 (Printer Module) cannot broadcast to an APR3-PRT1.
Likewise, a DGP
module cannot broadcast to a DGP2 module.
[4005] Quick Module Scanning:
After entering the section, the control panel will scan all addresses assigned to modules. If any missing modules are detected (i.e. detector
removed from the combus), the control panel will erase the module's serial number, removing the module from the control panel's memory.
[4006] Modules Scanning:
After entering the section, the control panel will scan all addresses on the combus. If any missing modules are detected (i.e. detector
removed from the combus), the control panel will erase the module's serial number, removing the module from the control panel's memory.
If new modules are detected, the serial number will be entered in the control panel’s memory.
[4010] Download from the Memory Key to the control panel except zone numbering and sections [0501] to [0532]. (See warning on page 50)
[4011] Download from the Memory Key to control panel including zone numbering and sections [0501] to [0532]. (See warning on page 50)
[4012] Download user labels from the Memory Key to control panel. (See warning on page 50)
[4013] Download installer default. (Use for reset from Memory key to control panel.)
[4020] Copy the control panel sections to the Memory Key except zone numbering and sections [0501] to [0532]. (See warning on page 50)
[4021] Copy the control panel sections to the Memory Key including zone numbering and sections [0501] to [0532]. (See warning on page 50)