Digiplex DGP2-641BL Manual de instalación Pagina 14

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 48
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 13
14 - Digiplex Modules Programming Guide
Magellan Wireless Expansion Module
The Module Broadcast feature of the Digiplex (DGP-848 and DGP-NE96) control panels is not supported by the Magellan Wireless
Expansion Module.
*For UL installations, check-in supervision must be enabled (ON).
Magellan’s PGM outputs are always enabled and are activated through the Magellan Remote Control (MG-REM1). Remote control button (refer to
page 15) controls PGM3 and remote control button controls PGM4 (if PGM4 is available). Press the appropriate button to activate the PGM that it controls.
Options [6] and [7] determine how the respective PGM will deactivate. If the option is OFF, the activated PGM will automatically deactivate after 2 seconds. If
the option is ON, each activated PGM can only be deactivated by pressing the appropriate button on a Magellan Remote Control that controls a PGM.
Assigning Wireless Detectors and Door Contacts to the Receiver
U = Default setting
SECTION [001] : Supervision
Option OFF ON The Magellan module automatically detects
the check-in time set in each of its assigned
transmitters. As a result, the transmitters can
have different check-in times.
[1] Low battery supervision
U Disabled
N Enabled
[2] Check-in supervision*
U Disabled
N Enabled
[3] Check-in supervision time interval
U 24 hours
N 80 minutes
[4] Future Use
UN/A
N N/A
[5] On-board module tamper supervision
U Disabled
N Enabled
[6]
PGM3 Deactivation
U
2 sec. Timer
N Manually
[7]
PGM4 Deactivation
U
2 sec. Timer
N Manually
[8] Ignore transmitter tamper signal N Ignore tamper
signal
N Report tamper
signal
Section(s) Description
[030] View unknown serial numbers of transmitters: By entering this section and by pressing the anti-tamper switch on the unknown
wireless detector or door contact, the module’s unknown serial number will be displayed.
[040] View and/or delete remote controls assigned in sections [201] to [208].
[041] View and/or delete remote controls assigned in sections [209] to [216].
[601] to [616] View the actual signal strength of the assigned wireless detectors and door contacts.
[701] to [716] View the actual battery life of the assigned wireless detectors and door contacts.
[801] to [816] View the previous battery life of the assigned wireless detectors and door contacts.
Section Input
Serial Number
(Detectors & Door Contacts)
Motion
Detector
Door
Contact
Section Input
Serial Number
(Detectors & Door Contacts)
Motion
Detector
Door
Contact
[101] 001 __/__/__/__/__/__ NN [109] 009 __/__/__/__/__/__ NN
[102] 002 __/__/__/__/__/__ NN [110] 010 __/__/__/__/__/__ NN
[103] 003 __/__/__/__/__/__ NN [111] 011 __/__/__/__/__/__ NN
[104] 004 __/__/__/__/__/__ NN [112] 012 __/__/__/__/__/__ NN
[105] 005 __/__/__/__/__/__ NN [113] 013 __/__/__/__/__/__ NN
[106] 006 __/__/__/__/__/__ NN [114] 014 __/__/__/__/__/__ NN
[107] 007 __/__/__/__/__/__ NN [115] 015 __/__/__/__/__/__ NN
[108] 008 __/__/__/__/__/__ NN [116] 016 __/__/__/__/__/__ NN
MG-RCV3 V2.0