Digiplex DGP-641 Especificaciones Pagina 16

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 22
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 15
Digiplex LCD Keypad 15n
2) Then enter the second digit, which can be any digit from 0 to F
depending on the first digit chosen.
3) After entering the second digit, use Feature Select Programming
to enable/disable options [1] to [8]. Each option represents a specific
event as detailed in the PGM Programming Table on the Digiplex
Programming Guide.
These keys represent the hexadecimal values from A to F:
[STAY] = A [ARM] = C [BYP] = E
[FORCE] = B [DISARM] = D [MEM] = F
5.3 PGM DEACTIVATION EVENT
Section 009
Once the PGM Activation Event (see section 5.2 of this manual) has
occurred, the keypad's on-board PGM will return to its normal state
(deactivate) when the event programmed in section [009] occurs
unless the keypad is in PGM Timed Mode (see section 5.4 of this
manual). The PGM Deactivation Event is programmed in the same
manner as the PGM Activation Event.
5.4 PGM TIMED MODE
Section 005: Option [2]
If the keypad is in PGM Timed Mode, the keypad's on-board PGM
will be deactivated according to the PGM Timer (see section 5.5 of
this manual) instead the PGM Deactivation Event.
Option [2] OFF = Deactivates on PGM Deactivation Event (default)
Option [2] ON = PGM will deactivate according to the PGM Timer
Vista de pagina 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 22

Comentarios a estos manuales

Sin comentarios