14 Installer’s Guide
5.0 PGM PROGRAMMING
5.1 PGM STATE
Section 005: Option [1]
The keypad's on-board PGM can be set as normally open or
normally closed. When an open PGM is activated, it will close the
circuit from ground and enable any devices connected to it. When a
closed PGM is activated, it will open the circuit and disable any
devices connected to it. When the PGM Activation Event occurs (see
section 5.2 of this manual), the PGM will switch to its opposite state
(i.e. open to closed or closed to open).
Option [1] OFF = PGM is Normally Open (default)
Option [1] ON = PGM is Normally Closed
The PGM can provide 50mA to any device connected to it.
5.2 PGM ACTIVATION EVENT
Section 008
The PGM Activation Event determines which event(s) will activate
the keypad's on-board PGM. For details on the available activation
events, refer to the PGM Programming Table in the Digiplex
Programming Guide.
1) In section [008], key in the first digit where each digit from 8 to F
represents an event group (0 = PGM Disabled). The first digit
cannot be a value from 1 to 7.